The FST Measurement Libraries are provided as standard with 3030 Options 100 GSM/EDGE, 101 UMTS, and 102 cdma2000/1xEVDO. This example demonstrates the use of multiple FST Measurement Library .NET objects in Microsoft Visual C# .NET 2003 to control PXI hardware asynchronously. In this example, we configure the first FST instance to capture a sweep with burst triggering; the second FST instance is configured independently to generate a sweeping signal to capture.

  • Create two FST instances
  • Assign digitizer by resource, configure measurement
  • Assign siggen by resource strings and configure measurement
  • Enable required analysis
    - power
  • Make measurements
  • Retrieve measurement results

It assumes that the following has been installed successfully:

Hardware:
=========
Aeroflex 3011 RF Synthesizer PXI module
Aeroflex 303x RF Digitizer PXI module

Aeroflex 3010 RF Synthesizer PXI module
Aeroflex 302x RF Signal Generator PXI module

Software:
=========
Aeroflex PXI Module Software - V6.6.0 or better
At least one of the following:
Aeroflex GSM Measurement Suite - V2.6.0 or better
Aeroflex cdma2000/1xEVDO Measurement Suite - V2.6.0 or better
Aeroflex UMTS Measurement Suite - v3.4.0 or better

It is also assumed that:

The 3010 LO output is connected to the 3030 LO input
The 303x IF output is connected to the 303x IF input (if applicable)

The 3010 LO output is connected to the 3020 LO input
The 302x RF output is connected to the 303x RF input.


Disclaimer of Warranty

This example code is provided 'as is' without warranty.

Neither Aeroflex nor the author(s) warrant that the functions of the software will meet your requirements or that the media is compatible with any computer system on which it is used or that operation of the software will be unlimited or error free. You assume responsibility for selecting the software to achieve your intended results and for the installation of, the use of and the results obtained from the software. In no event shall Aeroflex or its suppliers be liable for any damages whatsoever arising out of installation of the software or incompatibility with any computer system or technical limitation of the software or use or inability to use the software, even if advised of the possibility of such damages. Neither Aeroflex nor the author(s) will be liable for any loss or damage of any nature suffered by any party as a result of reliance upon or reproduction of or any errors in any contents of the software.